LCD graphics display has text and mimic diagrams that display modes of operation, system parameters and alarms. Connect the device to a network using a 10 or 100 BASE-T connection. Green mode bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Battery failure notification provides early-warning fault analysis on batteries enabling timely preventive maintenance. Automatic internal bypass supplies utility power to the connected loads in the event of a UPS power overload or fault. Scalable runtime allows additional run time to be quickly added as needed. Intelligent battery management maximizes battery performance, life, and reliability through intelligent, precision charging.
- LCD graphics display - text and mimic diagrams that display modes of operation, system parameters and alarms
- 10/100 BaseT connection - connect the device to a network using a 10 or 100 BaseT connection
- Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
- Scalable runtime - allows additional run time to be quickly added as needed
- Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
- Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
- Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
- Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
- Scalable runtime - allows additional run time to be quickly added as needed
- Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
- Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
- Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
- Plug-and-Play external batteries - ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
- Rack/tower convertible - protects the initial investment in the UPS when migrating from tower to rack-mount environment
- Flash upgradeable firmware - install maintenance releases of firmware remotely using FTP
- User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
- Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement
- Disconnected battery notification - warns when a battery is not available to provide backup power
- Audible alarms - provides notification of changing utility power and UPS power conditions
- Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery
- Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances
- Input power factor correction - minimizes installation costs by enabling the use of smaller generators and cabling
- Generator compatible - ensures clean, uninterrupted power to protected equipment when generator power is used
- Cold-start capable - provides temporary battery power when the utility power is out
- Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms. - 10/100 BaseT сonnection
Connect the device to a network using a 10 or 100 BaseT connection. - Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. - Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance. - Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault. - Scalable runtime
Allows additional run time to be quickly added as needed. - Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging. - Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. - Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power. - Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature. - Network manageable
Provides remote power management of the UPS over the network. - InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager. - SmartSlot
Customize UPS capabilities with management cards. - LED status indicators
Quickly understand unit and power status with visual indicators. - Serial connectivity
Provides management of the UPS via a serial port. - Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. - Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment. - Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP. - User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement. - Disconnected battery notification
Warns when a battery is not available to provide backup power. - Audible alarms
Provides notification of changing utility power and UPS power conditions. - Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances. - Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling. - Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used. - Cold-start capable
Provides temporary battery power when the utility power is out. - Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Main Specifications
Product Description | APC Smart-UPS SRT 5000VA RM - UPS - 4500 Watt - 5000 VA |
Manufacturer Warranty | 3 years warranty |
Dimensions (WxDxH) | 43.2 cm x 71.9 cm x 13 cm |
Weight | 54.55 kg |
Networking | USB |
Device Type | UPS - rack-mountable |
Battery | Lead Acid |
Input Voltage | AC 230 V |
Output Voltage | AC 230 V ± 3% |
Colour | Black |
Rack Size | 3U |
Run Time (Up To) | 4 min at full load |
Power Capacity | 4500 Watt / 5000 VA |
Input Connectors | Hardwire 3-wire (1PH + N + G) |
Output connectors | 6 x power IEC 60320 C13 4 x power IEC 60320 C19 2 x IEC connector |
Extended Specifications
Battery |
---|
Technology | Lead Acid |
|
Run Time (Up To) | 4 min at full load 11.8 min at half load |
|
Recharge Time | 3 hours |
|
Features | Maintenance free, sealed, leak-proof |
|
Dimensions & Weight |
---|
Width | 43.2 cm |
|
Depth | 71.9 cm |
|
Height | 13 cm |
|
Weight | 54.55 kg |
|
Dimensions & Weight (Shipping) |
---|
Shipping Width | 61 cm |
|
Shipping Depth | 96 cm |
|
Shipping Height | 33 cm |
|
Shipping Weight | 63.6 kg |
|
Environmental Parameters |
---|
Min Operating Temperature | 0 °C |
|
Max Operating Temperature | 40 °C |
|
Humidity Range Operating | 0 - 95% (non-condensing) |
|
Sound Emission | 55 dBA |
|
Expansion / Connectivity |
---|
Interfaces | 1 x serial - RJ-45 1 x management (USB) - 4 pin USB Type B 1 x EPO (emergency power off) |
|
Expansion Slots | 1 (total) / 1 (free) x SmartSlot |
|
General |
---|
Device Type | UPS - rack-mountable |
|
Height (Rack Units) | 3U |
|
Colour | Black |
|
|
Miscellaneous |
---|
Features | Audible alarm, LCD display |
|
Compliant Standards | C-Tick, VDE, IEC 60950, EN 50091-2, RoHS, EN 50091-1, REACH, EN 62040-2, IP20, EAC |
|
Networking |
---|
Remote Management Interface | USB |
|
Power Device |
---|
UPS Technology | On-line |
|
Input Voltage | AC 230 V |
|
Frequency Provided | 50/60 Hz |
|
Frequency Required | 45 - 65 Hz |
|
Input Connectors | Hardwire 3-wire (1PH + N + G) |
|
Power Output Connectors Details | 6 x power IEC 60320 C13 4 x power IEC 60320 C19 2 x IEC connector |
|
Output Voltage | AC 230 V ± 3% - 50/60 Hz |
|
Power Capacity | 4500 Watt / 5000 VA |
|
Output Waveform | Sinewave |
|
Surge Suppression | Yes |
|
Surge Energy Rating | 480 Joules |
|
Efficiency | 98% |
|
Warranty
|
Manufacturer Warranty |
---|
Service & Support | Limited warranty - 3 years Limited warranty - batteries - 2 years |